Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
2.
Eur Heart J Acute Cardiovasc Care ; 12(11): 782-791, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37812760

RESUMO

AIMS: The role of coronary calcification on clinical outcomes among different revascularization strategies in patients presenting with acute coronary syndromes (ACSs) has been rarely investigated. The aim of this investigation is to evaluate the role of coronary calcification, detected by coronary angiography, in the whole spectrum of patients presenting with acute ACS. METHODS AND RESULTS: The present study was a post hoc analysis of the MATRIX programme. The primary endpoint was major adverse cardiovascular events (MACE), defined as the composite of all-cause mortality, myocardial infarction (MI), or stroke up to 365 days. Among the 8404 patients randomized in the MATRIX trial, data about coronary calcification were available in 7446 (88.6%) and therefore were included in this post hoc analysis. Overall, 875 patients (11.7%) presented with severe coronary calcification, while 6571 patients (88.3%) did not present severe coronary calcification on coronary angiography. Fewer patients with severe coronary calcification underwent percutaneous coronary intervention whereas coronary artery bypass grafting or medical therapy-only was more frequent compared with patients without severe calcification. At 1-year follow-up, MACE occurred in 237 (27.1%) patients with severe calcified coronary lesions and 985 (15%) patients without severe coronary calcified lesions [hazard ratio (HR) 1.91; 95% confidence interval (CI) 1.66-2.20, P < 0.001]. All-cause mortality was 8.6% in patients presenting with and 3.7% in those without severe coronary calcification (HR 2.38, 1.84-3.09, P < 0.001). Patients with severe coronary calcification incurred higher rate of MI (20.1% vs. 11.5%, HR 1.81; 95% CI 1.53-2.1, P < 0.001) and similar rate of stroke (0.8% vs. 0.6%, HR 1.35; 95% CI 0.61-3.02, P = 0.46). CONCLUSION: Patients with ACS and severe coronary calcification, as compared to those without, are associated with worse clinical outcomes irrespective of the management strategy.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Humanos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
JACC Cardiovasc Interv ; 16(15): 1833-1844, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37587590

RESUMO

Guiding catheter extensions (GCEs) have become indispensable tools in the modern approach to percutaneous coronary intervention (PCI). The support offered during complex PCI of uncrossable, or tortuous lesions is particularly valuable in the setting of chronic total occlusions (CTO), both for conventional anterograde wire escalation and for anterograde or retrograde dissection and re-entry techniques. This EuroCTO consensus document describes the use of GCE during CTO recanalization and provides a practical guide to anatomies and techniques in which these devices are applicable. We describe the peculiar features of the most-used device and the practical technique for GCE delivery in standard PCI; further specific indications for antegrade and retrograde CTO PCI are discussed in a specific section. In the antegrade approach, the GCEs may be useful to increase support or facilitate antegrade dissection and re-entry techniques, while in the retrograde approach for reverse controlled antegrade and retrograde tracking, to increase retrograde support for gear delivery, for treatment of CTO in bifurcation and ipsilateral externalization with a single guide catheter. The last section of the paper describes GCE-related complications, challenges, limitations, and future perspectives.


Assuntos
Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Cateteres , Consenso , Dissecação
4.
JACC Cardiovasc Interv ; 16(15): 1873-1886, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37587595

RESUMO

BACKGROUND: A simple, contemporary risk score for the prediction of contrast-associated acute kidney injury (CA-AKI) after percutaneous coronary intervention (PCI) was recently updated, although its external validation is lacking. OBJECTIVES: The aim of this study was to validate the updated CA-AKI risk score in a large cohort of acute coronary syndrome patients from the MATRIX (Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of angioX) trial. METHODS: The risk score identifies 4 risk categories for CA-AKI. The primary endpoint was to appraise the receiver-operating characteristics of an 8-component and a 12-component CA-AKI model. Independent predictors of Kidney Disease Improving Global Outcomes-based acute kidney injury and the impact of CA-AKI on 1-year mortality and bleeding were also investigated. RESULTS: The MATRIX trial included 8,201 patients with complete creatinine values and no end-stage renal disease. CA-AKI occurred in 5.5% of the patients, with a stepwise increase of CA-AKI rates from the lowest to the highest of the 4 risk categories. The receiver-operating characteristic area under the curve was 0.67 (95% CI: 0.64-0.70) with model 1 and 0.71 (95% CI: 0.68-0.74) with model 2. CA-AKI risk was systematically overestimated with both models (Hosmer-Lemeshow goodness-of-fit test: P < 0.05). The 1-year risks of all-cause mortality and bleeding were higher in CA-AKI patients (HR: 7.03 [95% CI: 5.47-9.05] and HR: 3.20 [95% CI: 2.56-3.99]; respectively). There was a gradual risk increase for mortality and bleeding as a function of the CA-AKI risk category for both models. CONCLUSIONS: The updated CA-AKI risk score identifies patients at incremental risks of acute kidney injury, bleeding, and mortality. (Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of angioX [MATRIX]; NCT01433627).


Assuntos
Síndrome Coronariana Aguda , Injúria Renal Aguda , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 102(2): 221-232, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232278

RESUMO

BACKGROUND: Data about the long-term performance of new-generation ultrathin-strut drug-eluting stents (DES) in challenging coronary lesions, such as left main (LM), bifurcation, and chronic total occlusion (CTO) lesions are scant. METHODS: The international multicenter retrospective observational ULTRA study included consecutive patients treated from September 2016 to August 2021 with ultrathin-strut (<70 µm) DES in challenging de novo lesions. Primary endpoint was target lesion failure (TLF): composite of cardiac death, target-lesion revascularization (TLR), target-vessel myocardial infarction (TVMI), or definite stent thrombosis (ST). Secondary endpoints included all-cause death, acute myocardial infarction (AMI), target vessel revascularization, and TLF components. TLF predictors were assessed with Cox multivariable analysis. RESULTS: Of 1801 patients (age: 66.6 ± 11.2 years; male: 1410 [78.3%]), 170 (9.4%) experienced TLF during follow-up of 3.1 ± 1.4 years. In patients with LM, CTO, and bifurcation lesions, TLF rates were 13.5%, 9.9%, and 8.9%, respectively. Overall, 160 (8.9%) patients died (74 [4.1%] from cardiac causes). AMI and TVMI rates were 6.0% and 3.2%, respectively. ST occurred in 11 (1.1%) patients while 77 (4.3%) underwent TLR. Multivariable analysis identified the following predictors of TLF: age, STEMI with cardiogenic shock, impaired left ventricular ejection fraction, diabetes, and renal dysfunction. Among the procedural variables, total stent length increased TLF risk (HR: 1.01, 95% CI: 1-1.02 per mm increase), while intracoronary imaging reduced the risk substantially (HR: 0.35, 95% CI: 0.12-0.82). CONCLUSIONS: Ultrathin-strut DES showed high efficacy and satisfactory safety, even in patients with challenging coronary lesions. Yet, despite using contemporary gold-standard DES, the association persisted between established patient- and procedure-related features of risk and impaired 3-year clinical outcome.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Sirolimo , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Função Ventricular Esquerda , Infarto do Miocárdio/etiologia , Desenho de Prótese , Stents/efeitos adversos , Sistema de Registros , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações
6.
Catheter Cardiovasc Interv ; 101(5): 918-931, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36883958

RESUMO

BACKGROUND: Gender-specific data addressing percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) in female patients are scarce and based on small sample size studies. AIMS: We aimed to analyze gender-differences regarding in-hospital clinical outcomes after CTO-PCI. METHODS: Data from 35,449 patients enrolled in the prospective European Registry of CTOs were analyzed. The primary outcome was the comparison of procedural success rate in the two cohorts (women vs. men), defined as a final residual stenosis less than 20%, with Thrombolysis In Myocardial Infarction grade flow = 3. In-hospital major adverse cardiac and cerebrovascular events (MACCEs) and procedural complications were deemed secondary outcomes. RESULTS: Women represented 15.2% of the entire study population. They were older and more likely to have hypertension, diabetes, and renal failure, with an overall lower J-CTO score. Women showed a higher procedural success rate (adjusted OR [aOR] = 1.115, confidence interval [CI]: 1.011-1.230, p = 0.030). Apart from previous myocardial infarction and surgical revascularization, no other significant gender differences were found among predictors of procedural success. Antegrade approach with true-to-true lumen techniques was more commonly used than retrograde approach in females. No gender differences were found regarding in-hospital MACCEs (0.9% vs. 0.9%, p = 0.766), although a higher rate of procedural complications was observed in women, such as coronary perforation (3.7% vs. 2.9%, p < 0.001) and vascular complications (1.0% vs. 0.6%, p < 0.001). CONCLUSIONS: Women are understudied in contemporary CTO-PCI practice. Female sex is associated with higher procedural success after CTO-PCI, yet no sex differences were found in terms of in-hospital MACCEs. Female sex was associated with a higher rate of procedural complications.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/complicações , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Infarto do Miocárdio/etiologia , Sistema de Registros , Doença Crônica , Angiografia Coronária/efeitos adversos
7.
J Invasive Cardiol ; 34(11): E763-E775, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36227013

RESUMO

OBJECTIVES: Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) can improve patient symptoms, but it remains controversial whether it impacts subsequent clinical outcomes. METHODS: In this systematic review and meta-analysis, we queried PubMed, ScienceDirect, Cochrane Library, Web of Science, and Embase databases (last search: September 15, 2021). We investigated the impact of CTO-PCI on clinical events including all-cause mortality, cardiovascular death, myocardial infarction (MI), major adverse cardiovascular event (MACE), stroke, subsequent coronary artery bypass surgery, target-vessel revascularization, and heart failure hospitalizations. Pooled analysis was performed using a random-effects model. RESULTS: A total of 58 publications with 54,540 patients were included in this analysis, of which 33 were observational studies of successful vs failed CTO-PCI, 19 were observational studies of CTO-PCI vs no CTO-PCI, and 6 were randomized controlled trials (RCTs). In observational studies, but not RCTs, CTO-PCI was associated with better clinical outcomes. Odds ratios (ORs) and 95% confidence intervals (CIs) for all-cause mortality, MACE, and MI were 0.52 (95% CI, 0.42-0.64), 0.46 (95% CI, 0.37-0.58), 0.66 (95% CI, 0.50-0.86), respectively for successful vs failed CTO-PCI studies; 0.38 (95% CI, 0.31-0.45), 0.57 (95% CI, 0.42-0.78), 0.65 (95% CI, 0.42-0.99), respectively, for observational studies of CTO-PCI vs no CTO-PCI; 0.72 (95% CI, 0.39-1.32), 0.69 (95% CI, 0.38-1.25), and 1.04 (95% CI, 0.46-2.37), respectively for RCTs. CONCLUSIONS: CTO-PCI is associated with better subsequent clinical outcomes in observational studies but not in RCTs. Appropriately powered RCTs are needed to conclusively determine the impact of CTO-PCI on clinical outcomes.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/cirurgia , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio/etiologia , Razão de Chances , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Observacionais como Assunto
8.
J Am Coll Cardiol ; 78(8): 840-853, 2021 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34412818

RESUMO

The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration.


Assuntos
Algoritmos , Angiografia Coronária , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea , Oclusão Coronária/diagnóstico por imagem , Humanos
9.
J Invasive Cardiol ; 33(3): E146-E154, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33570501

RESUMO

AIMS: Radiation exposure is a limiting factor for percutaneous coronary interventions (PCI) of chronic total coronary occlusion (CTO) lesions. This study was designed to analyze changes in patient radiation dose for CTO-PCI and parameters associated with radiation dose. METHODS AND RESULTS: We analyzed a cohort of 12,136 procedures performed by 23 operators between 2012 and 2017 from the European Registry of CTO-PCI. Radiation exposure was recorded as air kerma (AK) and dose area product (DAP). A dose rate index (DRI) was calculated as AK per fluoroscopy time to normalize for individual differences in fluoroscopy time. The lesion complexity increased from Japanese-CTO (J-CTO) score of 2.19 ± 1.44 to 2.46 ± 1.28, with an increase of retrograde procedures from 31.1% to 40.7%; still, procedural success improved from 87.7% to 92.1%. Fluoroscopy time remained similar, but AK decreased by 14.9%, from 2.35 Gy (interquartile range [IQR], 1.29-4.14 Gy) to 2.00 Gy (IQR, 1.08-3.45 Gy) and DAP decreased by 21.5%, from 130 Gy•cm² (IQR, 70-241 Gy•cm²) to 102 Gy•cm² (IQR, 58-184 Gy•cm²). Radiation exposure was determined by the lesion complexity (J-CTO score) and procedural complexity (antegrade or retrograde). DRI was determined by fluoroscopy frame rate and type of equipment used, but the major influence remained interoperator differences. CONCLUSIONS: Radiation exposure decreased during the observation period despite an increase in lesion and procedural complexity. While many operators already achieved a goal of low radiation exposure, there were considerable interoperator differences in radiation management, indicating further potential for improvement.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Exposição à Radiação , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Fluoroscopia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
10.
EuroIntervention ; 17(3): 212-219, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32894229

RESUMO

BACKGROUND: Equipment delivery in chronic total occlusion (CTO) percutaneous coronary intervention (PCI) can be challenging and it is associated with a higher risk of device entrapment. Data regarding the incidence of device entrapment during CTO PCI are lacking. AIMS: The aim of this study was to describe the incidence and procedural characteristics of device entrapment in patients undergoing PCI for CTOs and discuss management strategies for dealing with it. METHODS: Device entrapment was characterised in a large consecutive series of 2,361 CTO PCI cases performed by five high-volume CTO Italian operators between January 2015 and January 2020. RESULTS: Device entrapment occurred in 36 out of 2,361 cases (1.5%) and consisted of coronary guidewires in 13 (0.5%), microcatheters in 6 (0.2%), balloons in 6 (0.2%), rotational atherectomy burrs in 10 (0.4%) and guiding catheter extension in 1 patient (0.04%). Complete device retrieval was achieved in 63.9%, with at least partial removal of material in 97.2%. Vessel recanalisation was still possible in 86.1% of cases even after device entrapment. Intraprocedural myocardial infarction occurred in 3 patients (8.3%), tamponade with urgent pericardiocentesis in 1 (2.8%) and emergency surgical removal of the entrapped device in 1 patient (2.8%). Mean radiation dose was 4.7±2.3 Gy. At 30-day follow-up, one patient died with stent thrombosis of a non-target vessel and another required repeat percutaneous revascularisation. CONCLUSIONS: Device entrapment during CTO revascularisations is a rare but potentially severe complication. We describe and discuss current techniques of percutaneous retrieval that can be employed to achieve procedural success safely.


Assuntos
Aterectomia Coronária , Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Doenças Vasculares , Doença Crônica , Angiografia Coronária , Oclusão Coronária/epidemiologia , Oclusão Coronária/cirurgia , Humanos , Incidência , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 98(2): 238-245, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32857911

RESUMO

OBJECTIVES AND BACKGROUND: Coronary artery perforation (CAP) is a potentially life-threatening complication during percutaneous coronary interventions (PCI) and the best strategy for its management is yet to be proved. We aimed to analyze the safety, efficacy, and long-term clinical outcomes of the block and deliver (BAD) technique, as only anecdotal cases are reported in literature. METHODS: From January 2016 to January 2020, all consecutive patients treated with the BAD technique at five high-volume centers in Italy were retrospectively identified. RESULTS: 25 CAPs treated with the BAD technique were included. The most frequently perforated artery was the left anterior descending artery (32%) and spring-coil wires with a hydrophilic coating were the most common culprit wires (68%). Mean sealing time was 46.9 ± 60.1 min, with no significant differences between CTO-PCIs and non-CTO PCIs (p = .921). Acute successful sealing of the CAP was achieved in 96% of the cases. Immediate cardiac tamponade occurred in 28% of patients, four during CTO PCI and three during non-CTO PCI (p = .55). Two patients required pericardiocentesis during hospitalization, one patient developed acute kidney injury, and one patient underwent cardiac surgery due to severe mitral regurgitation. At 1-year follow-up no significant differences were observed between groups in terms of POCE (25 vs 25%, p = .628) and its individual components. CONCLUSION: The BAD technique proved to be effective for the management of CAP, showing high successful sealing rates. Rates of in-hospital events and at 1-year follow-up did not significantly differ between patients suffering CAP during CTO revascularization or during non-CTO PCI.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Int J Cardiol ; 323: 288-291, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-32858138

RESUMO

BACKGROUND: COronaVIrus Disease 19 (COVID-19) led to the reorganization of Cardiology Units in terms of working spaces and healthcare personnel. In this scenario, both outpatient visits and elective interventional cardiology procedures were suspended and/or postponed. We aimed to report the impact of COVID-19 on interventional coronary and structural procedures in Piedmont, Italy. METHODS: The number of coronary angiographies (CAG), percutaneous coronary interventions (PCI), primary PCI (pPCI), transcatheter aortic valve replacements (TAVR) and Mitraclip performed in Piedmont between March 1st and April 20th, 2020 (CoV-time) were collected from each catheterization laboratory and compared to the number of procedures performed the year before in the same months (NoCoV-time). RESULTS: Procedural data from 18 catheterization laboratories were collected. Both coronary (5498 versus 2888: difference: -47.5%; mean 305.4 VS 160.4; p = 0.002) and structural (84 versus 17: difference: -79.8%; mean 4.7 Vs 0.9; p < 0.001) procedures decreased during CoV-time compared to NoCoV-time. In particular, coronary angiographies (1782 versus 3460), PCI (1074 versus 1983), p PCI (271 versus 410), TAVR (11 versus 72) and Mitraclip (6 versus 12) showed a reduction of 48.5%, 45.7%, 33.7%, 84.7% and 50.0%, respectively (all p for comparison <0.05). CONCLUSIONS: Compared to the same time-period in 2019, both coronary and structural interventional procedures during COVID-19 epidemic suffered a dramatic decrease in Piedmont, Italy. Organizational change and structured clinical pathways should be created, together with awareness campaigns.


Assuntos
COVID-19/epidemiologia , Angiografia Coronária/estatística & dados numéricos , Intervenção Coronária Percutânea/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Humanos , Itália/epidemiologia , Valva Mitral/cirurgia , Pandemias
13.
Open Heart ; 7(2)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33122421

RESUMO

BACKGROUND: The role of planned angiographic control (PAC) over a conservative management driven by symptoms and ischaemia following percutaneous coronary intervention (PCI) of the unprotected left main (ULM) with second-generation drug-eluting stents remains controversial. PAC may timely detect intrastent restenosis, but it is still unclear if this translated into improved prognosis. METHODS AND ANALYSIS: PULSE is a prospective, multicentre, open-label, randomised controlled trial. Consecutive patients treated with PCI on ULM will be included, and after the index revascularisation patients will be randomised to PAC strategy performed with CT coronary after 6 months versus a conservative symptoms and ischaemia-driven follow-up management. Follow-up will be for at least 18 months from randomisation. Major adverse cardiovascular events at 18 months (a composite endpoint including death, cardiovascular death, myocardial infarction (MI) (excluding periprocedural MI), unstable angina, stent thrombosis) will be the primary efficacy outcome. Secondary outcomes will include any unplanned target lesion revascularisation (TLR) and TLR driven by PAC. Safety endpoints embrace worsening of renal failure and bleeding events. A sample size of 550 patients (275 per group) is required to have a 80% chance of detecting, as significant at the 5% level, a 7.5% relative reduction in the primary outcome. TRIAL REGISTRATION NUMBER: NCT04144881.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
Catheter Cardiovasc Interv ; 96(4): E462-E466, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32187801

RESUMO

Coronary artery dissection is a well-known complication of percutaneous coronary interventions. In this setting, coronary artery dissection is caused by mechanical injury of the arterial wall. However, dissection may also occur spontaneously. In both situations, an intimal tear or dissection allows blood entering and separating the layers of the coronary arterial wall. Despite percutaneous approach is still the preferred and the quickest way to restore coronary flow, it remains challenging. One of the main reasons for procedural failure is due to the difficult advancement of a guidewire into the true lumen. In such situation, the ideal wire should have a soft tip, high torque control, and excellent flexibility. Assuming that, the "new rope coil" composite core Suoh 0.3 guidewire, with its unique combination of characteristics, could allow better orientation insight into a dissected coronary artery increasing the chance of procedural success. We collected a case series of nine consecutive patients in which the Suoh 0.3 guidewire was able to gain the true lumen distally to a dissected segment.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Anomalias dos Vasos Coronários/terapia , Doenças Vasculares/congênito , Anomalias dos Vasos Coronários/diagnóstico por imagem , Desenho de Equipamento , Humanos , Stents , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/terapia
15.
Circ Cardiovasc Interv ; 13(3): e008325, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32102566

RESUMO

BACKGROUND: There are limited data regarding the impact of final kissing balloon (FKI) in patients treated with percutaneous coronary intervention using ultrathin stents in left main or bifurcations. METHODS: All patients undergoing left main or bifurcations percutaneous coronary intervention enrolled in the RAIN registry (Very Thin Stents for Patients With MAIN or BiF in Real Life: The RAIN, a Multicenter Study) evaluating ultrathin stents were included. Major adverse cardiac event (a composite of all-cause death, myocardial infarction, target lesion revascularization, and stent thrombosis) was the primary end point, while its components, along with target vessel revascularization, were the secondary end points. The main analysis was performed comparing patients with and without FKI after adjustment with inverse probability of treatment weighting. Subgroup analyses were performed according to FKI (short [<3 mm] versus long overlap), strategy (provisional versus 2-stent), routine versus bail-out FKI, and the use of imaging and proximal optimization technique. RESULTS: Two thousand seven hundred forty-two patients were included. At 16 months (8-20) follow-up, inverse probability of treatment weighting adjusted rates of major adverse cardiac event were similar between FKI and no-FKI group (15.1% versus 15.5%; P=0.967), this result did not change with use of imaging, proximal optimization technique, or routine versus bail-out FKI. In the 2-stent subgroup, FKI was associated with lower rates of target vessel revascularization (7.8% versus 15.9%; P=0.030) and target lesion revascularization (7.3% versus 15.2%; P=0.032). Short overlap FKI was associated with a lower rate of target lesion revascularization compared with no FKI (2.6% versus 5.4%; P=0.034), while long overlap was not (6.8% versus 5.4%; P=0.567). CONCLUSIONS: In patients with bifurcations or unprotected left main treated with ultrathin stents, short overlap FKI is associated with less restenosis. In a 2-stent strategy, FKI was associated with less target vessel revascularization and restenosis. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03544294.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 96(5): 1037-1043, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31778041

RESUMO

OBJECTIVES: The aim of the study was to evaluate the outcomes of retrograde versus antegrade approach in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). BACKGROUND: The retrograde approach has increased the success rate of CTO PCI but has been associated with a higher risk for complications. METHODS: We conducted a meta-analysis of studies published between 2000 and August 2019 comparing the in-hospital and long-term outcomes with retrograde versus antegrade CTO PCI. RESULTS: Twelve observational studies (10,240 patients) met our inclusion criteria (retrograde approach 2,789 patients, antegrade approach 7,451 patients). Lesions treated with the retrograde approach had higher J-CTO score (2.8 vs. 1.9, p < .001). Retrograde CTO PCI was associated with a lower success rate (80.9% vs. 87.4%, p < .001). Both approaches had similar in-hospital mortality, urgent revascularization, and cerebrovascular events. Retrograde CTO PCI was associated with higher risk of in-hospital myocardial infarction (MI; odds ratio [OR] 2.37, 95% confidence intervals [CI] 1.7, 3.32, p < .001), urgent pericardiocentesis (OR 2.53, 95% CI 1.41-4.51, p = .002), and contrast-induced nephropathy (OR 2.12, 95% CI 1.47-3.08; p < .001). During a mean follow-up of 48 ± 31 months retrograde crossing had similar mortality (OR 1.79, 95% CI 0.84-3.81, p = .13), but a higher incidence of MI (OR 2.07, 95% CI 1.1-3.88, p = .02), target vessel revascularization (OR 1.92, 95% CI 1.49-2.46, p < .001), and target lesion revascularization (OR 2.08, 95% CI 1.33-3.28, p = .001). CONCLUSIONS: Compared with antegrade CTO PCI, retrograde CTO PCI is performed in more complex lesions and is associated with a higher risk for acute and long-term adverse events.


Assuntos
Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Mortalidade Hospitalar , Humanos , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Circulation ; 140(5): 420-433, 2019 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-31356129

RESUMO

Outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) have improved because of advancements in equipment and techniques. With global collaboration and knowledge sharing, we have identified 7 common principles that are widely accepted as best practices for CTO-PCI. 1. Ischemic symptom improvement is the primary indication for CTO-PCI. 2. Dual coronary angiography and in-depth and structured review of the angiogram (and, if available, coronary computed tomography angiography) are key for planning and safely performing CTO-PCI. 3. Use of a microcatheter is essential for optimal guidewire manipulation and exchanges. 4. Antegrade wiring, antegrade dissection and reentry, and the retrograde approach are all complementary and necessary crossing strategies. Antegrade wiring is the most common initial technique, whereas retrograde and antegrade dissection and reentry are often required for more complex CTOs. 5. If the initially selected crossing strategy fails, efficient change to an alternative crossing technique increases the likelihood of eventual PCI success, shortens procedure time, and lowers radiation and contrast use. 6. Specific CTO-PCI expertise and volume and the availability of specialized equipment will increase the likelihood of crossing success and facilitate prevention and management of complications, such as perforation. 7. Meticulous attention to lesion preparation and stenting technique, often requiring intracoronary imaging, is required to ensure optimum stent expansion and minimize the risk of short- and long-term adverse events. These principles have been widely adopted by experienced CTO-PCI operators and centers currently achieving high success and acceptable complication rates. Outcomes are less optimal at less experienced centers, highlighting the need for broader adoption of the aforementioned 7 guiding principles along with the development of additional simple and safe CTO crossing and revascularization strategies through ongoing research, education, and training.


Assuntos
Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Doença Crônica , Circulação Colateral/fisiologia , Angiografia Coronária/métodos , Angiografia Coronária/normas , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
19.
G Ital Cardiol (Rome) ; 20(2): 117-119, 2019 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-30747927

RESUMO

The majority of myxomas are located in the left atrium (75%) followed by the right atrium (20%). In rare cases, myxomas can be found in the ventricles, with 2.5% reported for myxomas in the left ventricle. Systemic emboli, mostly cerebral, occur in two thirds of such patients, while coronary emboli are rare. Here we report a case of left ventricular myxoma causing infero-postero-lateral myocardial infarction, successfully treated by intracoronary thromboaspiration of myxoma embolus.


Assuntos
Embolia/diagnóstico , Neoplasias Cardíacas/complicações , Infarto do Miocárdio/etiologia , Mixoma/complicações , Adulto , Embolia/complicações , Feminino , Neoplasias Cardíacas/diagnóstico , Ventrículos do Coração/patologia , Humanos , Mixoma/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...